Explosion-proof frequency converter station type ChPSV UHL5
Explosion-proof frequency converter station type ChPSV-500/1140-UKhLS is designed for stepless electrical control of the speed and torque of the belt conveyor drive and supplying power supply to the auxiliary devices of the station and conveyor in underground mine workings hazardous for gas (methane) and coal dust .
The station is designed to work together with various automatic control systems (Davis Derby, Promos, AUK, etc.). The station can operate in the “Local”, “Remote” and “Telecontrol” modes. The station has intrinsically safe control and signaling circuits; communication with the dispatcher is carried out via an explosion-proof fiber-optic communication line.
Specifications
No., p/p | Parameter | Meaning |
---|---|---|
1 | Rated voltage, V | 1140 |
2 | Rated power of the connected motor, kW | up to 500 |
3 | Rated current, A | 266 |
4 | Motor torque control range,% | 0..100 |
5 | Maximum developed torque on the motor shaft,% | 150, no more than 1 min |
6 | Range of regulation of rotation speed of electric motors,% | 10..100 |
7 | Current regulation range of electric motors,% | 10..100 |
8 | Asynchronous motor control method | vector control |
9 | Power of connected cooling fan motors conveyor drive electric motor, kW | up to 50 |
10 | Power of connected electric hydraulic pushers of the drive brake, kW | to 10 |
eleven | Cooling system | liquid/single-circuit |
12 | Shell protection degree | IP 54 |
13 | Explosion protection marking | RV Exd[ia op is]ia I X |
The equipment provides
- stepless electrical control of speed and torque;
- operational local and remote control of the electric drive;
- mechanical and electrical interlocks;
- control of auxiliary motors of the brake cooling circuit, motor drives and other auxiliary equipment;
- electrical motor protection (in ANSI codes);
- data transmission via RS-485 interface, ModBUS protocol;
- connection to a fiber-optic communication line;
- maintaining logs of emergency events.
Working conditions:
- ambient temperature +1..+35 degrees;
- relative ambient humidity up to 100% at a temperature of +35 degrees;
- absence of sharp shocks and impacts;
- dust content of the surrounding air is not more than 1000 mg/m3;
- the working position in space is horizontal, deviation from the working position is allowed up to 15 degrees in any direction;
Reliability indicators:
- mean time between failures - at least 8000 hours;
- the established resource before the first major overhaul is at least 65,000 hours;
- average full service life - at least 15 years;
- average recovery time is no more than 2 hours.