Water refrigeration unit type UVH
Water refrigeration unit type UVX is explosion-proof electrical equipment of group I with explosion protection level Mb and type of explosion protection “C” (structural safety protection) and is intended for: cooling electrical and non-electrical machines and mechanisms with an internal liquid cooling circuit; for use in underground areas of mines, as well as in those parts of surface installations of such mines that may be at risk of explosion as a result of exposure to firedamp and/or combustible dust.
Specifications
No. p/p | Parameter | Meaning |
---|---|---|
1 | Quantity, from mains | Z |
2 | Rated voltage of the supply circuit, V | 380 / 660 |
3 | Rated frequency, Hz | 50 |
4 | Pump motor type/explosion protection marking | AIU-M-80 / RV Exd I Мь |
5 | Pump motor rated power, kW | 2.2 |
6 | Fan motor type/explosion protection marking | AIUK 132S4 / RV Exd I Мь Х |
7 | Fan motor rated power, kW | 7.5 |
8 | Level switch type/explosion protection marking | Level relay RUG-1-Ex-G / OExia ll Ct6 X |
9 | Minimum cooling power Rhol., kW | 50 |
10 | Estimated heat transfer of the radiator, kW | 300 |
eleven | Radiator cooling element material | Copper |
12 | Total volume of coolant in the installation, l | 500 |
13 | The total designated service life of the installation is, years | 10 |
14 | Mean time between failures, h | 7000 |
15 | Lifetime before first major overhaul, h | 20000 |
16 | Overall dimensions (width, height, depth), mm | 1550 x 863 x 402 |
17 | Weight (without coolant), kg, no more | 530 |
Country of origin:
Russia